1Korea testing Laboratory, Material Technology Center, 87, Digital-ro 26gil, Guro-gu 08389, Seoul, Republic of Korea
2Agency for Defense Development, Institute of Civil-Military Technology Cooperation, Yuseong P.O. Box 35, Daejeon, 34186, Republic of Korea
3Ceratorq Inc., 8, Ori-ro, 651beon-gil, Gwangmyeong, 14303, Gyeonggi-do, Republic of Korea
Cite this as
Cha JS, Kim TW, Lee YS, Kim BK, Jang SK. Method for Measuring Apparent Densities of Zeolite Nanopowders using Piezoelectric Energy. Int J Nanomater Nanotechnol Nanomed. 2024;10(2):073-080. Available from: 10.17352/2455-3492.000065Copyright License
© 2024 Cha JS, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.This study investigated factors influencing the flowability of zeolite using three types of commercial zeolites with low flowability – Zeolite-beta, Zeolite-Y, and ZSM-5 - and manufactured a device applying piezoelectric energy to measure their apparent density. Zeolite properties such as flow function (FF) and cohesion by Powder Rheometer, elemental analysis by XRF, specific surface area, pore characteristics, and shape of zeolite particles by FE-SEM, average particle size and size distribution by particle size analyzer were analyzed. Low flowability zeolite could pass through a mesh hole moved by piezoelectric energy. The apparent density measured by the device applying piezoelectric energy was found to be more uniform with a smaller standard deviation than existing density measurement equipment.
Powder density is one of the basic properties dictating the efficiency of many processes [1]. Powder densities are typically quantified as apparent (bulk), tapped, relative, and true (absolute) densities [2]. The apparent density of a powder is the ratio of the mass of an untapped powder sample and its volume including the contribution of inter-particulate void volume [3,4]. International standard test methods for powder apparent density have been defined in various fields. Powder apparent density measurement methods standardized by International Organization for Standardization (ISO) include ISO 697 (Surface active agents – Washing powder - Determination of apparent density – Method by measuring the mass of a given volume), ISO 3923-1 (Metallic powders-Determination of apparent density-Part 1: Funnel method), ISO 9161 (Uranium dioxide powder-Determination of apparent density and tap density), ISO 23145-2 (Fine ceramics (advanced ceramics, advanced technical ceramics) - Determination of bulk density of ceramic powders – Part 2: Untapped density), and so on. These methods can measure the apparent density by calculating the mass of powder placed in a known volume container after passing through a funnel with a certain size orifice in a hoper of a certain height. To apply these methods, the powder must have flowability to pass through the orifice of the funnel. For powders that could not pass through the orifice due to low flowability, various studies have published methods to measure the apparent density using modified devices such as orifice size adjustment, vibrating funnel, modified feeding system, and so on [5-8].
Flowability is defined as the ability of a powder to flow freely regularly and constantly [9]. Flowability is affected by various properties of the powder. Ansari et al. have reported that powder flowability is not an inherent material property, but the result of a combination of many factors such as particle size, shape, particle interaction, packing fraction, flow rate, temperature, humidity, and electrostatic charge [10]. Stavrou et al. have also reported that powder flow is not an inherent material property but is dependent on material physical properties [11]. In the present study, a density measurement device using piezoelectric energy was developed to measure the apparent density of low-flowability powder. Piezoelectric transducers can be used to convert kinetic energy (i.e., mechanical vibration) into electrical energy (direct piezoelectric effect) or vice versa (inverse piezoelectric effect) [12-15]. These piezoelectric transducers are widely used because of their merits of simple structure, fast response, and low power consumption [16]. For example, a quartz crystal microbalance (QCM) is based on the piezoelectric effect that occurs in crystalline materials of certain crystallography [17]. QCM has been used to measure a mass variation per unit area by measuring the change in frequency of a quartz crystal resonator. QCM has been reported of exceptional importance in the fields of (bio)sensors, material science, and environmental monitoring [18]. Also, piezoelectric microbalance has been applied as a transducer for the mass of vacuum-deposited films and the mass of vapors and gases adsorbed by coatings on the crystal surface [19].
Ultrasonic vibration systems using piezoelectric transducers have been applied to various fields [20-22]. In this study, we developed a density measurement system using a piezoelectric transducer for measuring low-flowability powder. This system is similar to a conventional density measurement device except that it generates mechanical vibration to pass through a hole such as an orifice.
In this study, three types of commercial zeolites were selected as low-flowability powders. Zeolites are crystalline inorganic microporous solids formed by TO4 tetrahedra (with T=Si, Al, P, Ge, B, among others), whose structures enclose channels and/or cavities of varying size and shape [23,24]. Due to their specific pore sizes and large surface areas, zeolites have the potential for a wide range of applications such as molecular sieves, adsorbents, and catalysts [25,26]. It has been reported that the particle size of zeolite can affect reactivity [27,28]. To improve the performance of zeolite, it is necessary to apply smaller-size zeolite. However, particle size reduction can negatively impact powder flowability [29,30]. Therefore, in this study, we first studied the effects of the characteristics of three types of commercial zeolites on flowability and attempted to verify the density measurement protocol of the apparent density measurement system using piezoelectric energy.
Zeolite-beta (ACS Material LLC, USA), zeolite-Y (Zeolyst, USA), and ZSM-5 (ACS Material LLC, USA) referred to as Z-B, Z-Y, and Z-5, respectively, were selected in this study. They are widely used as adsorbents and catalyst supports. Zeolite samples were heated in a convection oven for over 6 h at 110℃ and cooled in a vacuum desiccator to room temperature.
Flowability and cohesion of zeolite were measured using a Powder Rheometer (FT4, Micromeritics). This powder rheometer can measure flow resistance while the blade moves through the zeolite powder. By measuring the rotation and vertical resistance while the blade moved through the powder, torque, and force values were obtained and then used as powder flow resistance. In this way, Flow Function (FF) and cohesion were measured. Chemical compositions of zeolites were analyzed by XRF (X-ray Fluorescence, ZSX Primus Ⅳ, Rigaku), Specific surface area and pore characteristics (pore size and volume) were analyzed using N2 adsorption & desorption equipment after pretreatment at 150℃ for over 6 h. The shape of zeolite particles was analyzed by FE-SEM. Average particle size and size distribution were analyzed by particle size analyzer. Ethanol was used as a zeolite dispersion solvent. Before analysis, agglomerated particles were dispersed for 3 min using an ultrasonic dispersion device.
Figure 1 shows a conceptual diagram of the apparent density measurement system using piezoelectric energy. It was designed to allow zeolite powder to easily pass through the sample holder by applying a piezoelectric transducer that could generate an ultrasonic vibration on a mesh plate. Figure 2(a) shows a mesh plate and Figure 2(b) shows a mesh hole designed in the form of a sieve net consisting of several mesh holes in the center. Zeolite powder on the funnel could pass through the mesh hole moved by the piezoelectric energy.
The mesh plate was designed to have an O.D. of 38 mm and an I.D. of 14 mm. The mesh hole was designed to have a square shape with an area of 0.5 mm × 0.5 mm. The mesh hole size was determined based on results obtained from a conventional apparent density measurement device. The piezoelectric transducer was manufactured by attaching piezoelectric ceramic to a mesh plate. In this study, piezoelectric ceramic with a thickness of less than 0.5 mm and an I.D. of 10 mm was used. The piezoelectric transducer was connected to an oscilloscope and set a frequency where the phase difference between the input voltage and the consumed current is 00 (or a frequency where the phase difference is close to 00).
To measure the apparent density of zeolite powder, the mass (m0) of a measuring container with a known empty volume was measured. The container was placed at the bottom of the funnel. According to the ISO 23145-2 standard, zeolite powder was put into a funnel with orifice sizes of 2.5, 5.0, and 10.0mm, respectively. Whether it passed through the orifice was then determined. If the zeolite powder passed through the orifice, the powder was allowed to flow into the measuring container until the container was filled with the powder and the powder overflowed its periphery. After removing the cone of surplus powder by cutting it flat with a sample knife, the mass of the measuring container containing the sample was measured (m1). The apparent density of zeolite powder was obtained according to the following equation (1):
Where m0 was the mass of the empty measuring container (g), m1 was the mass of the measuring container full of the powder (g), and V was the volume of the measuring container (cm
When utilizing the apparent density measurement system using piezoelectric energy, each type of zeolite was added into the funnel shown in Figure 1. Vibration was then generated on the mesh plate to which the piezoelectric transducer was applied. Zeolite powder then passed through the mesh hole. The apparent density was determined with the same procedures as described in ISO 23145-2.
Table 1 shows flow function and cohesion results with a Powder Rheometer. Rheology is the study of the deformation and flow of matter [31]. Flow function measured with a Powder Rheometer represents the relationship between shear stress and normal stress of zeolite powder. The shear stress was plotted in terms of the normal stress, which is also known as τ-σ diagram [32]. The higher the shear stress for a given normal stress, the lower the flow of the powder. The shear testing protocol developed by Jenike in 1964 has been commonly used to characterize powder flow. This protocol requires measurement of consolidated stress required to shear a powder bed under a series of normal consolidation stresses [33]. Major principal stress (σ1) and unconfined yield strength (σc) were identified through Mohr stress circles fitting to each yield trajectory. The ratio of the two can be expressed as a flow function (FF) as shown in equation (2)
Where σ1 is the principal stress and σc is the unconfined yield strength.
Table 1 shows results at a vertical stress of 3 kPa. The higher the FF, the better the flowability. In this study, Z-B had the best flowability, followed by Z-5 and Z-Y. According to Jenike’s FF classification, Z-Y and Z-5 with 2 < FF < 4 had a ‘cohesive’ flow behavior and Z-B with 4 < FF < 10 had an ‘easy-flowing’ behavior [34].
In addition, as shown in Table 1, the cohesion of Z-Y was the highest, followed by Z-5 and Z-B. This means that powders with higher cohesion have lower flowability. This result has also been reported by other researchers. Leung et al. have reported that flow function (FF) is predominantly governed by cohesion [35]. Wilkinson et al. have also reported that more cohesive powder shows poorer flowability (higher flow energy) [36].
To determine the effects of the characteristics of zeolite powder on flowability, the chemical compositions of zeolite powders were analyzed by XRF. Results are summarized in Table 2. All zeolites contained more than 90% SiO2. Z-B and Z-Y had slightly higher SO3 than Z-5. Z-B had higher CaO content than other zeolites but had lower contents of SO3 and CaO (below 0.5wt. %). However, the chemical compositions of zeolites were found to be similar to each other.
Table 3 shows the results of the specific surface area, pore size, and volume of zeolites. Z-Y had the highest specific surface area, followed by Z-B and Z-5. However, Z-B had the largest pore volume, followed by Z-Y and Z-5, unlike results for the specific surface area. This was because the pore size of Z-B was relatively large, resulting in a large total pore volume, whereas Z-5 had micropores of less than 2 nm. Thus, the total pore volume of Z-5 was relatively low. Fitzpatrick et al. have reported that the particle surface area per unit mass is increased when particle size is decreased. When the specific surface area is increased, the surface area to interact is also increased, resulting in a more cohesive flow behavior [37]. In this study, Z-Y, which had the highest specific surface area, had the lowest flowability. However, the flowability and specific surface area didn’t match for Z-B and Z-5. Abdullah et al. have also reported that the higher the specific surface area, the lower the flowability [38]. Their result was because the specific surface area increased as the particle size decreased in the same type of particulate material. However, such a result was not shown in the present study because zeolites had different pore characteristics.
Figure 3 shows the particle size distribution of zeolites. Z-B and Z-Y showed a normal distribution with mean sizes of about 450 nm and 750 nm, respectively, while Z-5 showed a double particle size distribution at 3.5 um and 80 um. Thus, the particle size of Z-5 was not uniform. Rosland Abel et al. have reported that when the particle size is reduced, the flowability is also reduced generally [34,39]. However, in the present study, Z-B having the smallest average particle size had the highest flowability. Other researchers have also reported that flowability is increased when powder has a narrower size distribution [40,41]. However, in the present study, Z-Y having the narrowest particle size distribution showed the lowest flowability, different from the results of previous studies.
FE-SEM was used to examine the particle size and shape of zeolite particles. Results are shown in Figure 4. Z-B showed a shape in which small particles less than 100 nm were agglomerated. Z-Y had an irregular shape with a larger size. Although Z-B and Z-Y had uniform particle sizes, Z-5 had particles of various sizes, similar to the results of particle size analysis. Although particle size analysis results revealed that Z-B had a wide size distribution with particle sizes of 100 nm or more, FE-SEM showed that smaller particles of Z-B were agglomerated. This indicates that Z-B cannot be dispersed into primary particles even through ultrasonic dispersion. The above results, including flow function and particle size distribution, are for agglomerated secondary particles.
Many researchers have reported that powder flowability is affected by shape factors [31,42]. We calculated the roundness and circularity of each zeolite particle based on an FE-SEM image using Image J software (version 1.54) [43]. Open the SEM image in the Image J program, and separate the color of the target particle and the background using the internal software. And then, select the range of particles to be measured using the threshold, and then calculate the size, roundness, etc. Results are shown in Figure 4 and Table 4.
When measuring the apparent density of zeolite, the size of the orifice (or mesh hole) that the zeolite particle must pass through was 2.5 to 10.0 mm. When passing through the orifice (or mesh hole) of this size, zeolite particles are expected to pass in a state of agglomerated secondary particles rather than in a state of primary particles. Thus, we analyzed the Roundness and Circularity of secondary particles using ImageJ software. Results shown in Table 4 are average values of Roundness and Circularity results from three FE-SEM images. The Roundness of zeolite secondary particles was calculated with equation (3) [44,45]:
Where A was the area of the zeolite particle and R was the large axis of the zeolite particle.
Z-B had the highest Roundness of about 0.67, followed by Z-5 and Z-Y. Kim et al. have reported that cohesiveness is stronger for powders with low roundness and explained that this is due to friction between oval-shaped particles or particles with satellite powders [34].
Particle Circularity is the degree to which particles resemble a circle. It was calculated with equation (4) [46]:
Where A was the area of the zeolite particle and P was the perimeter length of the zeolite particle.
Z-B also had the highest Circularity of 0.76, followed by Z-5 and Z-Y, similar to the results of Roundness. Liu et al. have performed theoretical analysis and reported that irregularly shaped particles have poor flowability [41]. This study also found that the lower the Roundness and Circularity, the lower the flowability.
Additionally, the irregularity of each zeolite was analyzed using ImageJ software. Irregularity evaluates the irregularity of particle shape based on the relationship between the diameter of the maximum inscribed circle (dimax) and that of the minimum circumscribed circle (dcmin). It was calculated with the following equation:
Where dimax was the diameter of the maximum inscribed circle and dcmin was the diameter of the minimum circumscribed circle.
When irregularity is close to 1, the particle is closer to having a sphere shape. As shown in Table 4, the Irregularity of Z-B was 1.50, which was the closest to 1, followed by Z-5 and Z-Y. These results were similar to the results of Roundness and Circularity. Various researchers have reported that spherical agglomeration or crystallization can improve the flowability [47-49]. It was believed that agglomerated secondary particles of Z-B showed higher flowability than other zeolites due to their relatively high sphericity.
In this study, the apparent density of zeolite was first measured according to the ISO 23145 Fine ceramics (advanced ceramics, advanced technical ceramics) - Determination of bulk density of ceramic powders – Part 2: Untapped density. According to the standard, if the sample cannot flow through the orifice funnel with a diameter of 2.5mm, an orifice funnel with a diameter of 5.0 mm could be used. As a result of apparent density according to the standard, Z-Y and Z-5 failed to pass the orifice funnel with diameters of 2.5 and 5.0 mm. Only Z-B passed the 5.0 mm orifice funnel as shown in Table 5. As described previously, according to Jenike’s FF classification, Z-B was ‘Easy-flowing’ while Z-Y and Z-5 were ‘Cohesive’. This characteristic was revealed when the apparent density was measured.
When apparent density was measured with a density measuring device that applied piezoelectric energy, simulation was first performed for acceleration changes according to mesh plate voltage. Figure 5 shows acceleration results for each piezoelectric transducer position at the resonant frequency. Change in acceleration according to voltage was expressed numerically, targeting the center with the highest acceleration.
In this simulation, equations (6) ~ (8) were applied to calculate acceleration [50]. Displacement of the piezoelectric transducer can be expressed with equation (6). When differentiated with time, it can be expressed as equation (7) for velocity and equation (8) for acceleration:
Where
x is a displacement (mm);
v is a velocity (m/s);l
a is an acceleration (m/s2); ㄱ
ω is an angular frequency;
t is a time(sec);
φ is an initial phase constant or phase angle;
A is an amplitude.
In equation (6), the maximum displacement is referred to as amplitude (A). When applying voltage V = 20V, the amplitude result by the simulation and the measurement using the laser displacement sensor (LK-H050, KEYENCE) are shown in Figure 6. a(t) max value was calculated to be 6.67×104 m/s2 by simulation, and 5.56×104 m/s2 by measurement, it was shown a deviation of approximately 17%.
As the voltage increased, the acceleration increased, which meant that the speed of zeolite passing through the metal plate hole was increased. As the voltage of the mesh plate increased, the measurement time was shortened, which could reduce errors such as moisture adsorption of zeolite during the measurement process. However, Vpp = 30 was applied and the mesh plate was heated. So the optimal voltage was selected at about 20 Vpp.
Table 5 summarizes the apparent density values of zeolites measured with a density-measuring device applying piezoelectric energy. To confirm the validity of these results, an orifice size of the ISO 23145 density measuring device was enlarged to 10.0 mm and results were compared. The apparent density measured by the density device using piezoelectric energy was found to be relatively lower than the density measured by ISO 23145 (orifice size = 10.0 mm). This was due to the sieving effect caused by the vibration of 0.5 mm mesh holes, where agglomerated zeolite powder was partially dispersed and filled into the measuring container. However, all agglomerated zeolite powder passed through the 10.0 mm orifice of the ISO 23145 device and filled into the measuring container. The standard deviation (SD) for three measurements was also calculated to be low with the density device using piezoelectric energy, showing more uniform results.
In this study, we examined factors influencing the flowability of zeolite for three types of commercial zeolite with low flowability, designed an apparent density measurement device using piezoelectric energy, and verified the apparent density measurement protocol of this device. The flowability of zeolite was found to be more affected by the shape of secondary particles, such as roundness, circularity, and irregularity, rather than by characteristics such as specific surface area, particle size, or distribution. In addition, on the apparent density measurement system using piezoelectric energy, the agglomerated zeolite powder was relatively dispersed due to a sieving effect of the mesh plate. As a result, the apparent density measurement system using piezoelectric energy showed lower density values than existing density measurement equipment. It also showed more uniform results with a smaller standard deviation (S.D).
This work was supported by the Industrial Strategic Technology Development Program-Nano product performance and safety evaluation technology development and corporate support project(20015633)-funded by the Ministry of Trade, Industry & Energy (MOTIE), Republic of Korea.
Subscribe to our articles alerts and stay tuned.
PTZ: We're glad you're here. Please click "create a new query" if you are a new visitor to our website and need further information from us.
If you are already a member of our network and need to keep track of any developments regarding a question you have already submitted, click "take me to my Query."